Codex Control Chart

Coming soon Chart

Track process variation and flag readings beyond control limits.

See it in action

Baseline held
See the held control limits and the Jan 19 point outside them.
Codex Control Chart: See the held control limits and the Jan 19 point outside them. Codex Control Chart: See the held control limits and the Jan 19 point outside them.
Individuals and moving range
Compare individual observations with the moving range below.
Codex Control Chart: Compare individual observations with the moving range below. Codex Control Chart: Compare individual observations with the moving range below.
Baseline held with data labels
Label key observations while keeping control limits in view.
Codex Control Chart: Label key observations while keeping control limits in view. Codex Control Chart: Label key observations while keeping control limits in view.
Stepped phase bands
Compare process phases using the sample readings and an illustrative change point.
Codex Control Chart: Compare process phases using the sample readings and an illustrative change point. Codex Control Chart: Compare process phases using the sample readings and an illustrative change point.

Overview

Use ordered observations for one process. For the daily fill-weight sample, each date has one daily process reading.

Ideal For

  • Track process variation and flag readings beyond control limits.

Key Features

  • Bind the date to Axis and a numeric measure to Values. Add Phase only if your data has meaningful process stages.
  • Start by checking that observations are in the right order. Compare baseline, mean and limits before investigating a flagged point. In the sample, the 19 January reading is outside the limits.
Pro Tip

Control limits describe observed variation; they are not customer specification limits. For a fixed two-decimal reading, give the measure an explicit numeric format such as 0.00.

Help guide

What goes in each field

Field well Put in Required What it does
Axis Date, time or ordered category Yes Defines the observation order. Use a real date for temporal data.
Values Numeric measure Yes One comparable process reading per observation.
Phase Column No Divides observations by a meaningful process change or regime.
Tooltips Fields No Extra context such as shift, batch or lot number.

Build the measure

Start with a single process measured consistently over time. The illustrative sample is one fill-weight reading per day. If your raw data has multiple rows every day, deliberately choose the statistic you want to monitor and use the same grain throughout. An average of daily measurements is not interchangeable with an individual measurement.

Daily mean fill weight =
AVERAGE ( FillWeight[Weight] )

Use the sample's equivalent value from its single reading per day, or your own measure. Check date order, duplicates and missing measurements in a built-in Table. Don't replace missing readings with zero unless zero is a real observation.

Put it together

  1. Bind the observation date to Axis and the measure to Values.
  2. Choose the style in Control chart. Start with Baseline held when you want a historical baseline to stay fixed as later readings arrive. Use Individuals and moving range to inspect readings alongside their moving ranges. Choose Stepped phase bands to compare phases after binding a Phase field.
  3. Set the baseline to a defensible set of comparable observations. Use Phase for real process changes, not just to make the chart look less noisy.
  4. Use Signals for the patterns you want to monitor and Data labels for emphasis. In Lines, turn on limit labels when the values are needed for review.
  5. After applying report filters, recheck the baseline and how many observations remain.

Walk through the sample

Baseline days 1–20 give a mean of 100.46, an upper control limit of 105.12, and a lower control limit of 95.79 in the held view. The 19 January point at 109.20 is beyond the upper limit. Compare that point with the moving-range panel in I-MR. A limit flag calls for investigation; it does not by itself name a root cause.

Tips and troubleshooting

  • A point is beyond a limit: check the reading, batch changes and measurement conditions before deciding what happened.
  • Limits are surprising: verify order, grain, phase boundaries and baseline. A specification limit is a customer or engineering requirement; a control limit describes observed process variation. They are not interchangeable.
  • Two decimals are missing: an explicit numeric model format such as 0.00 gives two decimals. If the host's literal C2 format does not match your Table in Automatic, use Axes → Fallback decimals → 2 for the numeric fallback.
  • The bottom axis is crowded: enlarge the visual or adjust axis font size and labels; the date ticks are thinned to fit. Do not infer that a hidden tick is a missing measurement.

For help, contact Nexus Codex support.

Planned launch pricing

US$1.79 per user/month

1–19 seats · not available to buy yet

Coming soon to AppSource
See planned volume pricing
Planned price per user (USD)
SeatsMonthlyAnnual
1–19$1.79$17.90
20–99$0.90$9.00
100–499$0.35$3.50
500–999$0.18$1.80
1,000–4,999$0.12$1.20
5,000–10,000$0.054$0.54

Category Chart
Tooltips
Cross-filtering
High Contrast